CORE ON / OFF HEAT PUMP R410-A

Core On / Off Heat Pump R410A

  • A Energy Class for a higher and more efficient performance
  • Blow Xfan to eliminate unwanted moisture in indoor unit
  • Achieve power saving and improved heating efficiency thanks to Intelligent Defrost
Categories: ,

CORE ON / OFF HEAT PUMP R410-A

Core On / Off Heat Pump R410A

  • A Energy Class for a higher and more efficient performance
  • Blow Xfan to eliminate unwanted moisture in indoor unit
  • Achieve power saving and improved heating efficiency thanks to Intelligent Defrost

Features

  • A Energy Class
    High energy efficiency
  • Blow Xfan
    With a touch of a button on the remote control your air conditioner cleans itself! The process only takes 17 minutes. When it is finished, the unit is ready to be used again, clean from bacteria and fungi, providing fresh and clean air.
  • Intelligent Defrost
    Power saving and improved heating efficiency by intelligent defrost. Intelligent Defrost is achieved only by sensors that they control the need and duration of defrost process.

Specs

MODELAPSI – 09 / APSO – 09

  • Cooling Capacity9,000 Btu / h
  • Cooling Capacity2.64 kWatt
  • Heating Capacity9,600 Btu / h
  • Heating Capacity2.81 kWatt
  • LESS EER3.22 W / W
  • COP3.61 W / W
  • Energy ClassA / A
  • Voltage / Frequency / Phase230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling4.60 A
  • Current Input-Heating5.10 A
  • Power Input-Cooling821 W
  • Power Input-Heating779 W
  • Air Flow Volume (Hi / Med / Low)400 m³ / h
  • Noise Level-Indoor Unit37 (db(A))
  • Noise Level-Outdoor Unit50 (db(A))
  • Compressor TypeROTARY
  • Liquid line / Gas line1 / 4” / 3 / 8”
  • Dimensions -Indoor Unit WxDxH730 × 255 × 174 mm
  • Dimensions – Outdoor Unit WxDxH785 × 540 × 320 mm
  • Net Weight Indoor / Outdoor8 / 31 kg
  • RefrigerantR410A / 760g
  • Operation Temperature Range-Cooling18~43 ͦC
  • Operation Temperature Range-Heating-7~24 ͦC
  • Loading Quantities per 20’ / 40’HC116 / 280

MODELA1PSI – 12 / A1PSO – 12

  • Cooling Capacity11,000 Btu / h
  • Cooling Capacity3.22 kWatt
  • Heating Capacity11,997 Btu / h
  • Heating Capacity3.52 kWatt
  • LESS EER3.21 W / W
  • COP3.62 W / W
  • Energy ClassA / A
  • Voltage / Frequency / Phase230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling6.30 A
  • Current Input-Heating6.10 A
  • Power Input-Cooling1,004 W
  • Power Input-Heating973 W
  • Air Flow Volume (Hi / Med / Low)550 m³ / h
  • Noise Level-Indoor Unit38 (db(A))
  • Noise Level-Outdoor Unit52 (db(A))
  • Compressor TypeROTARY
  • Liquid line / Gas line1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH790 × 265 × 177 mm
  • Dimensions – Outdoor Unit WxDxH798 × 540 × 320 mm
  • Net Weight Indoor / Outdoor9 / 35 kg
  • RefrigerantR410A / 840g
  • Operation Temperature Range-Cooling18~43 ͦC
  • Operation Temperature Range-Heating-7~24 ͦC
  • Loading Quantities per 20’ / 40’HC110 / 269

MODELAPSI – 18 / APSO – 18

  • Cooling Capacity16,036 Btu / h
  • Cooling Capacity4.70 kWatt
  • Heating Capacity16,720 Btu / h
  • Heating Capacity4.90 kWatt
  • LESS EER3.22 W / W
  • COP3.43 W / W
  • Energy ClassA / B
  • Voltage / Frequency / Phase230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling10.00 A
  • Current Input-Heating10.00 A
  • Power Input-Cooling1,460 W
  • Power Input-Heating1,430 W
  • Air Flow Volume (Hi / Med / Low)850 m³ / h
  • Noise Level-Indoor Unit45 (db(A))
  • Noise Level-Outdoor Unit55 (db(A))
  • Compressor TypeROTARY
  • Liquid line / Gas line1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH940 × 298 × 200 mm
  • Dimensions – Outdoor Unit WxDxH848 × 540 × 320 mm
  • Net Weight Indoor / Outdoor10 / 40 kg
  • RefrigerantR410A / 1.150g
  • Operation Temperature Range-Cooling18~43 ͦC
  • Operation Temperature Range-Heating-7~24 ͦC
  • Loading Quantities per 20’ / 40’HC87 / 210

MODELA1PSI – 24 / A1PSO – 24

  • Cooling Capacity21,000 Btu / h
  • Cooling Capacity6.15 kWatt
  • Heating Capacity22,178 Btu / h
  • Heating Capacity6.50 kWatt
  • LESS EER3.24 W / W
  • COP3.42 W / W
  • Energy ClassA / A
  • Voltage / Frequency / Phase230 / 50 / 1 V / Hz / Ph
  • Current Input-Cooling11.30 A
  • Current Input-Heating11.70 A
  • Power Input-Cooling1,900 W
  • Power Input-Heating1,900 W
  • Air Flow Volume (Hi / Med / Low)850 m³ / h
  • Noise Level-Indoor Unit44 (db(A))
  • Noise Level-Outdoor Unit56 (db(A))
  • Compressor TypeROTARY
  • Liquid line / Gas line1 / 4” / 1 / 2”
  • Dimensions -Indoor Unit WxDxH940 × 298 × 200 mm
  • Dimensions – Outdoor Unit WxDxH913 × 680 × 378 mm
  • Net Weight Indoor / Outdoor13 / 46 kg
  • RefrigerantR410A / 1.450g
  • Operation Temperature Range-Cooling18~43 ͦC
  • Operation Temperature Range-Heating-7~24 ͦC
  • Loading Quantities per 20’ / 40’HC64 / 154

 

Benefits

Turbo Mode

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

24-hour Timer

Set the unit to start and stop automatically in a 24h period.

Auto Error Diagnosis

Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

Auto Restart

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

 

More

Automatic Operation

After setting the desired temperature, the unit will automatically adjust its operation in order to keep stable the temperature you have set

Auto Swing Louver

Distributes cool/warm air to maximum area by moving horizontal flaps automatically.

Two-way Draining

Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.

Anti-Cold Air Function

Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation