DUCTED

Ducted air conditioners. The business power for all conditions!

  • Super slim design for easy installation
  • Double air outlet from the back or the bottom side of the unit
  • Capability of a vent connection
  • Integrated water pump
Categories: ,

DUCTED

Ducted air conditioners. The business power for all conditions!

  • Super slim design for easy installation
  • Double air outlet from the back or the bottom side of the unit
  • Capability of a vent connection
  • Integrated water pump

The absolute solution
The Ducted indoor Multi Split units of Inventor ensure perfect conditions in the hardest cases when no one else can. With the integrated water pump, the fresh air intake and the capability to insert air from the back or the bottom side of the unit, they definitely are the most suitable solution even for the hardest installations. With 12.000 and 18.000 Btu/h capacity and 210mm height, they can be placed in all kinds of false ceilings.

Features
Super Slim Design
Smaller indoor unit’s height compared to the conventional indoor units.
Two Air Inlet Styles
Choose between the bottom or the rear side for the air intake. It can fit all needs of the installations. Flexible air intake from the back or the bottom part of the unit.
Fresh Air Intake
Provided to handle the fresh air load for a clean and healthy environment.
Built-in Drain Pump
The drain pump can lift the condensing water up to 750mm
Central Control Management (Optional)
The centralized multi-functional device can control up to 64 indoor units within a maximum connection length of 1200m.

Super slim design
Smaller indoor unit height compared to the conventional indoor units for easy installation even to false ceilings with restricted height. With 210mm height they provide great solutions.

Two air inlet styles
Flexible air intake from the back or the bottom part of the unit. It can fit all needs of an installation. Flexible connection due to the special stands of the unit.

Fresh air intake
Capability to connect a vent in order to enable fresh air load in the room. Flexible connection due to the special stands of the unit.

Built-in drain pump
The built-in drain pump is the absolute solution for the most difficult installations. Due to the fact that it can lift the condensing water up to 750mm you are able to select the placement of your air conditioning.

New “High Intelligence” Controller
Take advantage of the Weekly Planner and adjust according to your needs, the air conditioner’s operating period, ensuring maximum energy and money savings. The new advanced wired controller, shows up the error codes and additionally enables you to activate the room temperature sensor via the wired controller instead of the air conditioner.

Static Pressure Settings
With the advanced technology of the new air Duct units, you can set the available static pressure depending on your plant’s duct network, from 0Pa to 120Pa.

Technical Specifications
ModelLV4MDI – 07
Cooling Capacity7.000 Btu / h
Cooling Capacity2.05 kWatt
Heating Capacity8.000 Btu / h
Heating Capacity2.34 kWatt
LESS Voltage / Frequency / Phase220-240 / 50 / 1 V / Hz / Ph
Current Input – Cooling0.13 A
Current Input – Heating0.13 A
Power Input – Cooling30 W
Power Input – Heating30 W
Air Flow Volume (High / Medium / Low)530 / 400 / 340 m3 / h
Noise Level (Low / Medium / High) (dB )31 / 32 / 35 A
Sound Power Level (dB )55 A
Dimensions WxDxH700 × 210 × 635 mm
Net Weight18.5 kg
Liquid Line1 / 4”
Gas Line3 / 8”
Static Pressure0 – 45 Pa
ModelLV4MDI – 09
Cooling Capacity9.000 Btu / h
Cooling Capacity2.64 kWatt
Heating Capacity10.000 Btu / h
Heating Capacity2.93 kWatt
LESS Voltage / Frequency / Phase220-240 / 50 / 1 V / Hz / Ph
Current Input – Cooling0.13 A
Current Input – Heating0.13 A
Power Input – Cooling30 W
Power Input – Heating30 W
Air Flow Volume (High / Medium / Low)530 / 400 / 340 m3 / h
Noise Level (Low / Medium / High) (dB )28 / 31 / 35 A
Sound Power Level (dB )55 A
Dimensions WxDxH700 × 210 × 635 mm
Net Weight18.5 kg
Liquid Line1 / 4”
Gas Line3 / 8”
Static Pressure0 – 45 Pa
ModelLV4MDI – 12
Cooling Capacity12.000 Btu / h
Cooling Capacity3.52 kWatt
Heating Capacity13.000 Btu / h
Heating Capacity3.81 kWatt
LESS Voltage / Frequency / Phase220-240 / 50 / 1 V / Hz / Ph
Current Input – Cooling0.17 A
Current Input – Heating0.17 A
Power Input – Cooling40 W
Power Input – Heating40 W
Air Flow Volume (High / Medium / Low)600 / 480 / 300 m3 / h
Noise Level (Low / Medium / High) (dB )35 / 38 / 42 A
Sound Power Level (dB )59 A
Dimensions WxDxH700 × 200 × 450 mm
Net Weight18 kg
Liquid Line1 / 4”
Gas Line3 / 8”
Static Pressure0 – 60 Pa
ModelLV4MDI – 18
Cooling Capacity18.000 Btu / h
Cooling Capacity5.28 kWatt
Heating Capacity20.000 Btu / h
Heating Capacity5.86 kWatt
LESS Voltage / Frequency / Phase220-240 / 50 / 1 V / Hz / Ph
Current Input – Cooling0.48 A
Current Input – Heating0.48 A
Power Input – Cooling107 W
Power Input – Heating107 W
Air Flow Volume (High / Medium / Low)816 / 546 m3 / h
Noise Level (Low / Medium / High) (dB )40 / 42 / 46 A
Sound Power Level (dB )59 A
Dimensions WxDxH920 × 210 × 635 mm
Net Weight23.0 kg
Liquid Line1 / 4”
Gas Line1 / 2”
Static Pressure0 – 60 Pa

Benefits
Excellent Heating Performance Under -15°C
Excellent heating operation even in -15°C.

All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

Error Alarm Port
An indicator of an error code will appear if an error occurs.

Front Desk Control (Optional)
With a smart control board, air conditioners can be turned on/off via long distance control signals.

Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

24-hour Timer
Set the unit to start and stop automatically in a 24h period.

More
Flexible Installation
Maximum total pipe length up to 75m.
Wide Operation Range
With up to 25 stages (F1-F25) compressor frequency. The frequency range is increased as much as 70%, allowing the system to run smoothly.
Low Ambient Cooling
The outdoor unit’s special design produces an efficient and effective cooling operation even at -15°C.
Electronic Expansion Valve per Circuit
The independent electronic valve of each indoor unit, offers better operating control and efficiency.
5 Grades Outdoor Fan Speeds
Due to the DC fan motor, outdoor fan speeds increase from 2 grades to 5 grades, more comfortable and reinforces energy saving.
Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Smart Controller
Take advantage of the 4 choices to adjust the indoor unit’s fan speed and benefit from the Filter Cleaning Reminder mode, the Louver Position Memory, the Temperature Compensation sensor and the Higher/ Lower Temperature settings to create the ideal conditions in your place.

 

Reviews

There are no reviews yet.

Be the first to review “DUCTED”
Shopping Cart